VMONEN=DISABLED, VBATLI=VBAT_IS_LOW, VBATRSTF=VBAT_IS_BELOW_RESET, VBATLIEN=DISABLED, VBATHITHEN=DISABLED
Module Control
VBATRSTF | VBAT Reset Threshold Status Flag. 0 (VBAT_IS_BELOW_RESET): The VBAT voltage is below the VBAT reset threshold. 1 (VBAT_IS_ABOVE_RESET): The VBAT voltage is above the VBAT reset threshold. |
VBATLI | VBAT Low Interrupt Flag. 0 (VBAT_IS_LOW): The VBAT voltage is below the early warning threshold. 1 (VBAT_IS_OK): The VBAT voltage is above the early warning threshold. |
VBATHITHEN | VBAT High Threshold Enable. 0 (DISABLED): Use the standard VBAT thresholds. 1 (ENABLED): Use the high VBAT thresholds. |
VBATLIEN | VBAT Low Interrupt Enable. 0 (DISABLED): Disable the VBAT low interrupt. 1 (ENABLED): Enable the VBAT low interrupt. |
VMONEN | VBAT Supply Monitor Enable. 0 (DISABLED): Disable the VBAT supply monitor. 1 (ENABLED): Enable the VBAT supply monitor. |